Saturday, February 9, 2019

SULFUR RESISTANT CEMENT CEM I 42.5 R SR5



SULFUR RESISTANT CEMENT   CEM I  42.5 R  SR5


A hydraulic cement produced by milling Portland cement clinker containing max 5% tricalcium aluminates together with a given quantity of gypsum.
Produced in compliance with TS 10157 standards.
Typically SDC 32,5 can be used in places where ordinary Portland cement is used. Since it has a C3A ratio less than 5% it is technically much more convenient in the areas that are subjected to higher sulfate rates such as tunnels, dam constructions, port constructions, irrigation channels, building chemicals etc. Fields of use include:
  • Shore and Port Structures
  • Off shore constructions
  • Disposed Water Facilities
  • Foundation, Bored Piles
  • Water Arcs
  • Dams
  • Underground water pipes, of concrete
  • Sulfate contaminated industrial grounds and structures
  • Refineries
  • Tunnel Shoring



Chemical analysisResults (%)Limit values
Silicon Oxide, % SiO219,26
Aluminium Oxide, % Al2O34,46
Iron Oxide, % Fe2O35,47
Calcium Oxide, % CaO61,47
Magnesium Oxide, % MgO1,46
Sulphur Oxide, % SO32,58≤ 4,0%
Sodium Oxide, % Na2O0,28
Potassium Oxide, % K2O0,62
CI0,0117≤ 0,10%
Loss on Ignition % ( L.O.I)3,19≤ 5,0%
Insoluble Residue % (I.R)0,29
Free Lime0,95
C3A2,57≤ 5,0%
2C3A+C4AF21,76≤ 25,0%

Physical analysisResultsLimit values
Initial Setting Time (minutes)160≥ 60
Final Setting Time (minutes)255
Soundness/Expansion (mm)1,0≤ 10
Specific Surface Area Blaine (cm2/g)3358
2 days - Compressive Strength (MPa)23,2≥ 20
7 days - Compressive Strength (MPa)38,9
28 days - Compressive Strength (MPa)51,8≥ 42,5; ≤ 62,5